783-A: Difference between revisions
Jump to navigation
Jump to search
(Created page with "Type '''783-A Output-Power Meter'''. ==Specifications== ==Links== ==Photos== <gallery> </gallery> Category:Meters") |
No edit summary |
||
(17 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{GR Product | |||
|model=783-A | |||
|codes=ABBEY | |||
|class=meters | |||
|summary=Output-power meter | |||
|image=GR 783-A Front.jpg | |||
|caption=General Radio 783-A Output-Power Meter | |||
|series= | |||
|introduced=1944 | |||
|discontinued=1961 | |||
|designers= | |||
|manuals= | |||
* [[Media:GR 783A Output-Power Meter 548 1960.pdf|General Radio 783-A Output-Power Meter Manual 548F (1967)]] | |||
{{Catalog History}} | |||
}} | |||
The {{Title|General Radio 783-A}} is an Output-Power Meter introduced in {{Catalog K2}} that remained available through {{Catalog Q}}. | |||
The 783-A is acts as an adjustable load impedance, with a voltmeter calibrated directly in watts dissipated in the load. | |||
It can safely handle 100 W at audio frequencies. | |||
It can be used to test amplifiers, transformers, oscillators, filters, and similar networks. | |||
{{Asbestos}} | |||
==Specifications== | ==Specifications== | ||
* '''Power Range:''' 0.2 mW to 100 W in five ranges | |||
* '''Impedance Range:''' 2.5 to 20,000 Ω | |||
* '''Power Accuracy:''' ±0.25 dB at full-scale reading. Overall frequency characteristic of power indication is flat within ±0.5 dB from 20 to 10,000 Hz; within 0.75 dB to 15,000 Hz | |||
==Links== | ==Links== | ||
* [[Media:GR Exp 783-A 02_1942.pdf|Experimenter February 1942 describing 783-A]] (OCRed) | |||
==Photos== | ==Photos== | ||
<gallery> | <gallery> | ||
GR 783-A Front.jpg | |||
GR 783-A Left Side.jpg | |||
GR 783-A Rear Inside.jpg | |||
GR 783-A Right Side.jpg | |||
GR 783-A Load Resistors.jpg| '''Asbestos Insulator''' | |||
GR 783-A Rear.jpg | |||
GR 783-A Case.jpg | |||
</gallery> | </gallery> | ||
[[Category:Meters]] | [[Category:Meters]] |
Latest revision as of 10:00, 30 June 2024
The General Radio 783-A is an Output-Power Meter introduced in Catalog K2 (1942) that remained available through Catalog Q (1961).
The 783-A is acts as an adjustable load impedance, with a voltmeter calibrated directly in watts dissipated in the load. It can safely handle 100 W at audio frequencies.
It can be used to test amplifiers, transformers, oscillators, filters, and similar networks.
- CAUTION: This device contains asbestos.
Specifications
- Power Range: 0.2 mW to 100 W in five ranges
- Impedance Range: 2.5 to 20,000 Ω
- Power Accuracy: ±0.25 dB at full-scale reading. Overall frequency characteristic of power indication is flat within ±0.5 dB from 20 to 10,000 Hz; within 0.75 dB to 15,000 Hz
Links
Photos
-
-
-
-
-
Asbestos Insulator
-
-