Type '''1140-A UHF Wavemeter'''.
{{GR Product
|model=1140-A
|codes=WAGER
|class=frequency standards and meters
|summary=UHF Wavemeter
|image=GR 1140-A Front.jpg
|caption=General Radio 1140-A UHF Wavemeter
|series=
|introduced=1948
|discontinued=1954
|designers=
|manuals=
"Manual Needed"
{{Catalog History}}
}}
The {{Title|General Radio 1140-A UHF Wavemeter}} was introduced in {{Catalog L}} and remained available through {{Catalog N}}.
The 1140-A is a simple device to measure frequency in the UHF range of 240 to 1200 MHz with 2% accuracy.  Behind the rear window is what is called a [[butterfly circuit]] which varies capacitance and inductance simultaneously to attain resonance.  Resonance is indicated with a microammeter.


==Specifications==
==Specifications==
* '''Frequency Range:''' 240-1200 MHz in one range
* '''Accuracy:''' ±2% of the indicated frequency
* '''Detector:''' A type 1N22 Crystal Detector (Microwave Diode)


==Links==
==Links==
 
* [[Media:GRwiki Exp 1140-A 10_1945.pdf|Experimenter describing Type 1140-A October 1945]]


==Photos==
==Photos==
<gallery>
<gallery>
GR 1140-A Front.jpg
GR 1140-A Inside Front.jpg
GR 1140-A Inside Left.jpg
GR 1140-A Inside Rear Butterfly B.jpg
GR 1140-A Inside Rear Butterfly.jpg
GR 1140-A Inside Rear.jpg
GR 1140-A Inside Right.jpg
GR 1140-A Bottom.jpg
</gallery>
</gallery>


[[Category:Frequency Standards and Meters]]
[[Category:Frequency Standards and Meters]]

Latest revision as of 20:07, 28 May 2024

General Radio 1140-A
UHF Wavemeter
General Radio 1140-A UHF Wavemeter

Available from 1948 to 1954

Manuals

"Manual Needed"

Catalog History
 Document Year Page
Catalog L 1948 196
Catalog M 1951 218
Catalog N 1954 224
(All manuals in PDF format unless noted otherwise)

The General Radio 1140-A UHF Wavemeter was introduced in Catalog L (1948) and remained available through Catalog N (1954).

The 1140-A is a simple device to measure frequency in the UHF range of 240 to 1200 MHz with 2% accuracy. Behind the rear window is what is called a butterfly circuit which varies capacitance and inductance simultaneously to attain resonance. Resonance is indicated with a microammeter.

Specifications

  • Frequency Range: 240-1200 MHz in one range
  • Accuracy: ±2% of the indicated frequency
  • Detector: A type 1N22 Crystal Detector (Microwave Diode)