1231-P5: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(2 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
Type 1231-P5 | {{GR Product | ||
|model=1231-P5 | |||
|codes=ALDER,ADOBE | |||
|class=detectors amplifiers | |||
|summary=Adjustable Filter | |||
|image=GR 1231-P5 Close-up.jpg | |||
|caption=General Radio 1231-P5 Adjustable Filter | |||
|series=1231 | |||
|introduced=1951 | |||
|discontinued=1959 | |||
|designers= | |||
|manuals= | |||
* '''Manual Needed''' | |||
{{Catalog History}} | |||
}} | |||
The {{Title|General Radio 1231-P5 Adjustable Filter}} was introduced in {{Catalog M}} and remained available through {{Catalog P}}. | |||
The Type 1231-P5 is designed as an accessory filter for the Type [[1231-B]] Amplifier and Null Detector. | |||
Its purpose is to increase selectivity, reduce noise and harmonics. | |||
The internal filters are parallel-resonant circuits, consisting of toroidal inductors and fixed capacitors for the 11 frequencies. | |||
Four additional switch positions are provided for selecting toroid inductors L1 thru L4 only. | |||
A pair of terminals for an external capacitor can be used for tuning the filter to any frequency from 20 Hz to 100 kHz. | |||
'''CAUTION:''' The Type 1231-P5 filter should not be subjected to any DC current. | |||
==Specifications== | |||
* '''Filter Frequencies:''' 11 settings; 50, 100, 200, 500 Hz; 1, 2, 5, 10, 20, 50, 100 kHz | |||
* '''Frequency Calibration:''' Within ±2% | |||
* '''Selectivity:''' Better than 30 dB against the second harmonic | |||
==Links== | |||
* [[Media:GR Exp 1231-P5 06_1951.pdf|Experimenter June 1951 describing Type 1231-P5]] | |||
==Photos== | |||
<gallery> | |||
GR 1231-P5 Front.jpg | |||
GR 1231-P5 Left.jpg | |||
GR 1231-P5 Rear.jpg | |||
GR 1231-P5 Right.jpg | |||
GR 1231-P5 Top Close-up.jpg | |||
GR 1231-P5 Bottom.jpg | |||
GR 1231-P5 Bottom Close-up.jpg | |||
</gallery> | |||
[[Category:Detectors Amplifiers]] | [[Category:Detectors Amplifiers]] |
Latest revision as of 22:43, 30 April 2024
The General Radio 1231-P5 Adjustable Filter was introduced in Catalog M (1951) and remained available through Catalog P (1959).
The Type 1231-P5 is designed as an accessory filter for the Type 1231-B Amplifier and Null Detector. Its purpose is to increase selectivity, reduce noise and harmonics.
The internal filters are parallel-resonant circuits, consisting of toroidal inductors and fixed capacitors for the 11 frequencies. Four additional switch positions are provided for selecting toroid inductors L1 thru L4 only. A pair of terminals for an external capacitor can be used for tuning the filter to any frequency from 20 Hz to 100 kHz.
CAUTION: The Type 1231-P5 filter should not be subjected to any DC current.
Specifications
- Filter Frequencies: 11 settings; 50, 100, 200, 500 Hz; 1, 2, 5, 10, 20, 50, 100 kHz
- Frequency Calibration: Within ±2%
- Selectivity: Better than 30 dB against the second harmonic