Latest revision as of 18:52, 16 April 2024
The General Radio 1264-A Modulating Power Supply was introduced in Catalog Q (1961) and remained available through Catalog S (1965).
The Type 1264-A was designed as a companion power supply-modulator for the Type 1361-A and other similar unit oscillators.
Amplitude modulation is provided by an internal 1 kHz square-wave oscillator, and pulse modulation is possible with the addition of an external driving source. The 1217-B Unit Pulse Generator is recommended as the external driver.
The 1264-B provides power through the standard unit power connector and modulation through a cable terminating in an eight-terminal "Jones" connector. The 1264-A can provide modulation to oscillators without the "Jones" connector by using adapters 1264-P1 and 1264-P2.
Specifications
- Regulated DC Output (Unmodulated)
- Voltage: Adjustable from 200 to 300 V
- Current: 50 mA maximum
- Ripple: Less than 5 mV
- Heater Output (Unregulated): 6.3 VAC / 2.1 A
- Modulation: internal 1 kHz square-wave