The '''General Radio 1156-A Decade Scaler''' introduced in {{Catalog S}} and remained available through {{Catalog T}}. | The '''General Radio 1156-A Decade Scaler''' was introduced in {{Catalog S}} and remained available through {{Catalog T}}. | ||
The 1156-A is a 10 to 1 divider used to pre scale the input signal to a frequency meter or counter. Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument. Included are covers for the relocated connector holes to make a clean installation. | The 1156-A is a 10 to 1 divider used to pre scale the input signal to a frequency meter or counter. Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument. Included are covers for the relocated connector holes to make a clean installation. |
Revision as of 02:11, 4 April 2024
The General Radio 1156-A Decade Scaler was introduced in Catalog S (1965) and remained available through Catalog T (1968).
The 1156-A is a 10 to 1 divider used to pre scale the input signal to a frequency meter or counter. Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument. Included are covers for the relocated connector holes to make a clean installation.
Specifications
- Input: DC to 100 MHz
- Output: DC to 10 MHz
- Sensitivity: 0.1, 0.2, 0.5, and 1 Vp-p at 50 Ω; 1 Vp-p at 500 Ω
- Input Impedance: 50 Ω or 500 Ω, switch-selected
- Output Impedance: 250 Ω
Links
Photos
-
-
-
-
-
-
Combination Type 1150-B and 1156-A