1021-P1: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 11: | Line 11: | ||
|manuals= | |manuals= | ||
* [[Media:GR 1021A Signal Generator 1021-100-G 1964.pdf|General Radio 1021-A Standard Signal Generator Manual 1021-100-G 1964]] | * [[Media:GR 1021A Signal Generator 1021-100-G 1964.pdf|General Radio 1021-A Standard Signal Generator Manual 1021-100-G 1964]] | ||
{{Catalog History}} | |||
* [[Media:GRwiki Catalog M OCR 1951.pdf|M (1951)]], p.134 | |||
* [[Media:GRwiki Catalog N OCR 1954.pdf|N (1954)]], p.146 | |||
* [[Media:GRwiki Catalog O OCR 1956.pdf|O (1956)]], p.92 | |||
* [[Media:GRwiki Catalog P OCR 1959.pdf|P (1959)]], p.90 | |||
* [[Media:GRwiki Catalog Q OCR 1961.pdf|Q (1961)]], p.90 | |||
* [[Media:GRwiki Catalog R OCR 1963.pdf|R (1963]], p.124 | |||
* [[Media:GRwiki Catalog S OCR 1965.pdf|S (1965)]], p.151 | |||
}} | }} | ||
The '''General Radio 1021-P1''' is the power supply and case for the Type 1021-A series of UHF and VHF Standard Signal Generators. | The '''General Radio 1021-P1''' is the power supply and case for the Type 1021-A series of UHF and VHF Standard Signal Generators. |
Revision as of 09:05, 29 March 2024
The General Radio 1021-P1 is the power supply and case for the Type 1021-A series of UHF and VHF Standard Signal Generators. It was introduced in Catalog N in 1951, and remained available through Catalog S, 1965.
The Type 1021-P1 provides all the voltages for the oscillator unit use plus modulator and voltage indication. The 1021-P1 is a regulated plate supply plus regulated filament supply to the oscillator unit. The power supply will not operate without an oscillator unit installed.
Specifications
- Power Input: 50 W at 115 VAC.
- Modulator: 1000 Hz AM and provision for external modulation of 30 Hz to 15 kHz AM.