Specifications
- Capacitance: 1 pF to 1100 μF in 7 ranges.
- Inductance: 1 μH to 1100 H in 7 ranges.
- Resistance: 1 mΩ to 11 MΩ in 8 ranges.
- Conductance: ac or dc, 1 n℧ to 1.1 ℧ in 7 ranges.
- D: (series capacitance) 0.001 to 1 at 1 kHz, (parallel capacitance) 0.1 to 50 at 1 kHz.
- Q: (series inductance) 0.02 to 10 at 1 kHz, (parallel inductance) 1 to 1000 at 1 kHz.
- Basic accuracy: ±1% of full scale, ±5% for dissipation factor.
- Internal oscillator: 1 kHz ±2%.
- Frequency range: 20 Hz to 20 kHz (to 100 kHz with reduced accuracy).