1021-P1: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 10: | Line 10: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:GR 1021A Signal | * [[Media:GR 1021A Signal Generator 1021-100-G 1964.pdf|General Radio 1021-A Standard Signal Generator Manual 1021-100-G 1964]] | ||
}} | }} | ||
The '''General Radio 1021-P1''' is | The '''General Radio 1021-P1''' is the power supply and case for the Type 1021-A series of UHF and VHF Standard Signal Generators. | ||
and remained available through Catalog S 1965 | It was [[introduced in 1951|in Catalog N in 1951]], and remained available through Catalog S, 1965. | ||
The Type 1021-P1 provides all the voltages for the oscillator unit use plus modulator and voltage indication. | |||
The 1021-P1 is a regulated plate supply plus regulated filament supply to the oscillator unit. | |||
The power supply will not operate without an oscillator unit installed. | |||
==Specifications== | ==Specifications== |
Revision as of 04:21, 29 February 2024
The General Radio 1021-P1 is the power supply and case for the Type 1021-A series of UHF and VHF Standard Signal Generators. It was in Catalog N in 1951, and remained available through Catalog S, 1965.
The Type 1021-P1 provides all the voltages for the oscillator unit use plus modulator and voltage indication. The 1021-P1 is a regulated plate supply plus regulated filament supply to the oscillator unit. The power supply will not operate without an oscillator unit installed.
Specifications
- Power Input: 50 W at 115 VAC.
- Modulator: 1000 Hz AM and provision for external modulation of 30 Hz to 15 kHz AM.
Links
- Experimenter describing Type 1021-A 1950
- Experimenter describing Type 1021-A and Type 1021-P3A 1955
- Experimenter describing Type 1021-P10 1957