1216-A: Difference between revisions
No edit summary |
No edit summary |
||
(9 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{GR Product | {{GR Product | ||
|model=1216-A | |model=1216-A | ||
|class=detectors | |codes=AMONG,1216-9701 | ||
|summary=Unit | |class=amplifiers and detectors | ||
|summary=Unit IF amplifier | |||
|image=GR 1216-A Front Close-up.jpg | |image=GR 1216-A Front Close-up.jpg | ||
|caption=General Radio 1216-A Unit IF Amplifier | |caption=General Radio 1216-A Unit IF Amplifier | ||
|series= | |||
|introduced=1954 | |introduced=1954 | ||
|discontinued=1968 | |discontinued=1968 | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:GR 1216-A Unit IF Amplifier and DNT Detector 1216-0100-G 7_1961.pdf|General Radio 1216-A Unit IF Amplifier and DNT Detector Manual 1216-0100-G 1961]] | |||
* [[Media:GR 1216-A IF Amplifier and DNT Detectors 839-F 1960.pdf|General Radio 1216-A Unit IF Amplifier and DNT Detector Manual 839-F 1960]] | * [[Media:GR 1216-A IF Amplifier and DNT Detectors 839-F 1960.pdf|General Radio 1216-A Unit IF Amplifier and DNT Detector Manual 839-F 1960]] | ||
{{Catalog History}} | {{Catalog History}} | ||
}} | }} | ||
The | The {{Title|General Radio 1216-A Unit IF Amplifier}} was introduced in {{Catalog N}} and remained available through {{Catalog T}}. | ||
The Type 1216-A is an high gain amplifier operating at a fixed frequency of 30 MHz with a bandwidth of 0.7 MHz. | |||
Combined with a unit oscillator and mixer, it forms what General Radio called a DNT detector, which in its simplest form is a radio receiver whose frequency range is determined by the selected unit oscillator. | |||
The 1216-A is equipped with a meter for signal strength measurements using its built in attenuator. | |||
The meter can switched to monitor the input to the amplifier. | |||
An AVC function located on the attenuator switch is advantageous when using the 1216-A in the null detector role. | |||
The 1216-A contains its own power supply and connection for suppling power to an external unit oscillator. | |||
Front-panel binding posts provide an output of the demodulated signal. | |||
The recommended mixer for DNT applications is the [[874-MR]] with an upper frequency limit of 5 GHz. | |||
==Specifications== | ==Specifications== |
Latest revision as of 02:39, 16 October 2024
The General Radio 1216-A Unit IF Amplifier was introduced in Catalog N (1954) and remained available through Catalog T (1968).
The Type 1216-A is an high gain amplifier operating at a fixed frequency of 30 MHz with a bandwidth of 0.7 MHz.
Combined with a unit oscillator and mixer, it forms what General Radio called a DNT detector, which in its simplest form is a radio receiver whose frequency range is determined by the selected unit oscillator.
The 1216-A is equipped with a meter for signal strength measurements using its built in attenuator. The meter can switched to monitor the input to the amplifier. An AVC function located on the attenuator switch is advantageous when using the 1216-A in the null detector role.
The 1216-A contains its own power supply and connection for suppling power to an external unit oscillator. Front-panel binding posts provide an output of the demodulated signal.
The recommended mixer for DNT applications is the 874-MR with an upper frequency limit of 5 GHz.
Specifications
- Center Frequency: 30 MHz
- Bandwidth: 0.7 MHz at 3 dB down; 9.5 MHz at 60 dB down
- Attenuator Range: 0 to 70 dB in 10 dB steps, a single 3 dB step is also provided
- Sensitivity: Less than 2 μV input from a 400 Ω source required for a 1% meter deflection (above noise). Less than 50 μV input from a 400 Ω source required for full-scale meter deflection. Input voltages referred to are open circuit source voltages.