1201-B: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{GR Product
{{GR Product
|model=1201-B
|model=1201-B
|codes=ALIVE,ALIVERALLY
|codes=ASSET
|class=power supplies
|class=power supplies
|summary=Unit Regulated Power Supply
|summary=Unit Regulated Power Supply
Line 11: Line 11:
|designers=
|designers=
|manuals=
|manuals=
* [[Media:GR 1201-B Regulated Power Supply 1201-0110-E 12_1961.pdf|General Radio 1201-B Regulated Power Supply Manual 1201-0110-E 1961]]
* [[Media:GR 1201-B Regulated Power Supply 912-D 07_1959.pdf|General Radio 1201-B Regulated Power Supply Manual 912-D 1959]]
* [[Media:GR 1201-B Regulated Power Supply 912-D 07_1959.pdf|General Radio 1201-B Regulated Power Supply Manual 912-D 1959]]
{{Catalog History}}
{{Catalog History}}
Line 30: Line 31:
==Links==
==Links==


* [[Media:GR Exp 1201-B 08_1958.pdf|Experimenter describing Type 1201-B August 1958]]
* [[Media:GR Exp 1201-B 08_1958.pdf|Experimenter August 1958 describing Type 1201-B]]
* [[1201-A]]
* [[1201-A]]
* [[1203-B|1203-B Unregulated Unit Power Supply]]
* [[1203-B|1203-B Unregulated Unit Power Supply]]

Latest revision as of 02:18, 16 October 2024

General Radio 1201-B
Unit Regulated Power Supply
General Radio 1201-B Unit Regulated Power Supply

Available from 1959 to 1963

Manuals
Catalog History
 Document Year Page
Catalog P 1959 143
Catalog Q 1961 137
Catalog R 1963 173
(All manuals in PDF format unless noted otherwise)

The General Radio 1201-B Unit Regulated Power Supply was introduced in Catalog P (1959) and remained available through Catalog R (1963). Separate versions were available for 105-125 V and 210-250 V line voltages.

The 300 V output is regulated within 1%, the filament supply is unregulated. Both power supplies are isolated from ground.

With its five-pin power connector located on the right side-panel, Type 1201-B is compatible with most Unit instruments.

Specifications

  • Outputs
  • High Voltage: 300 VDC (±1%) at 70 mA
  • Filament Votage: 6.3 VAC at 4 A (unregulated)
  • Regulation: DC output voltage is constant within ±¼% for all values of load current and line voltage