1201-B: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(5 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
{{GR Product | |||
|model=1201-B | |model=1201-B | ||
|codes=ASSET | |||
|class=power supplies | |class=power supplies | ||
|summary=Unit Regulated Power Supply | |summary=Unit Regulated Power Supply | ||
Line 10: | Line 11: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:GR 1201-B Regulated Power Supply 1201-0110-E 12_1961.pdf|General Radio 1201-B Regulated Power Supply Manual 1201-0110-E 1961]] | |||
* [[Media:GR 1201-B Regulated Power Supply 912-D 07_1959.pdf|General Radio 1201-B Regulated Power Supply Manual 912-D 1959]] | * [[Media:GR 1201-B Regulated Power Supply 912-D 07_1959.pdf|General Radio 1201-B Regulated Power Supply Manual 912-D 1959]] | ||
{{Catalog History}} | {{Catalog History}} | ||
}} | }} | ||
The {{Title|General Radio 1201-B Unit Regulated Power Supply}} was introduced in {{Catalog P}} and remained available through {{Catalog R}}. | The {{Title|General Radio 1201-B Unit Regulated Power Supply}} was introduced in {{Catalog P}} and remained available through {{Catalog R}}. | ||
Separate versions were available for 105-125 V and 210-250 V line voltages. | |||
The | The 300 V output is regulated within 1%, the filament supply is unregulated. Both power supplies are isolated from ground. | ||
With its five-pin power connector located on the right side-panel, Type 1201-B is compatible with most [[Unit instruments]]. | |||
==Specifications== | ==Specifications== | ||
* '''Outputs''' | * '''Outputs''' | ||
* '''High Voltage:''' | * '''High Voltage:''' 300 V<sub>DC</sub> (±1%) at 70 mA | ||
* '''Filament Votage:''' 6. | * '''Filament Votage:''' 6.3 V<sub>AC</sub> at 4 A (unregulated) | ||
* '''Regulation:''' DC output voltage is constant within ±¼ for all values of load current and line voltage | * '''Regulation:''' DC output voltage is constant within ±¼% for all values of load current and line voltage | ||
==Links== | ==Links== | ||
* [[Media:GR Exp 1201-B 08_1958.pdf|Experimenter describing Type 1201-B | * [[Media:GR Exp 1201-B 08_1958.pdf|Experimenter August 1958 describing Type 1201-B]] | ||
* [[1201-A]] | |||
* [[1203-B|1203-B Unregulated Unit Power Supply]] | |||
==Photos== | ==Photos== |
Latest revision as of 02:18, 16 October 2024
The General Radio 1201-B Unit Regulated Power Supply was introduced in Catalog P (1959) and remained available through Catalog R (1963). Separate versions were available for 105-125 V and 210-250 V line voltages.
The 300 V output is regulated within 1%, the filament supply is unregulated. Both power supplies are isolated from ground.
With its five-pin power connector located on the right side-panel, Type 1201-B is compatible with most Unit instruments.
Specifications
- Outputs
- High Voltage: 300 VDC (±1%) at 70 mA
- Filament Votage: 6.3 VAC at 4 A (unregulated)
- Regulation: DC output voltage is constant within ±¼% for all values of load current and line voltage