1114-A: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
Line 16: Line 16:
The {{Title|General Radio 1114-A Frequency Divider}} was introduced in {{Catalog Q}} and remained available through {{Catalog S}}.  
The {{Title|General Radio 1114-A Frequency Divider}} was introduced in {{Catalog Q}} and remained available through {{Catalog S}}.  


The Type 1114-A Frequency Divider is a component of the Type [[1105-A]] Frequency-Measurement Equipment.  Its designed to divide the 5 MHz input signal to produce 1Mhz output.  Subsequent modules, 1114-P2 thru 1114-P5 each divide by 10. Optional modules [[1114-P6]] and [[1114-P7]] provide 400 Hz and 60 Hz outputs. The output from the modules is essentially a sine wave, although 100 kHz and 10 kHz square wave output is available for the 1114-P2 and 1114-P3 respectivly.  The first divider 1114-P1 is a regerative 5:1 divider, 1114-P2 thru 1114-P5 are switching type 10:1 dividers.  The plug-in modules are designed to only fit in the correct slot. A switch behind the front cover selects the driving signal from 1 MHz 1114-P1 divider and an external 1 Mhz or 100 kHz inputs.
The Type 1114-A Frequency Divider is a component of the Type [[1105-A]] Frequency-Measurement Equipment.  Its designed to divide the 5 MHz input signal to produce 1Mhz output.  Subsequent modules, 1114-P2 thru 1114-P5 each divide by 10. Optional modules [[1114-P6]] and [[1114-P7]] provide 400 Hz and 60 Hz outputs. The output from the modules is essentially a sine wave, although 100 kHz and 10 kHz square wave output is available from the 1114-P2 and 1114-P3 respectively.  The first divider 1114-P1 is a regenerative 5:1 divider, 1114-P2 thru 1114-P5 are switching type 10:1 dividers.  The plug-in modules are designed to only fit in the correct slot. A switch behind the front cover selects the driving signal from 1 MHz 1114-P1 divider and an external 1 Mhz or 100 kHz inputs.


==Specifications==
==Specifications==

Revision as of 23:16, 5 August 2024

General Radio 1114-A
Frequency Divider
General Radio 1114-A Frequency Divider

Available from 1961 to 1965

Manuals
  • Manual Needed.
Catalog History
 Document Year Page
Catalog Q 1961 70
Catalog R 1963 89
Catalog S 1965 115
(All manuals in PDF format unless noted otherwise)

The General Radio 1114-A Frequency Divider was introduced in Catalog Q (1961) and remained available through Catalog S (1965).

The Type 1114-A Frequency Divider is a component of the Type 1105-A Frequency-Measurement Equipment. Its designed to divide the 5 MHz input signal to produce 1Mhz output. Subsequent modules, 1114-P2 thru 1114-P5 each divide by 10. Optional modules 1114-P6 and 1114-P7 provide 400 Hz and 60 Hz outputs. The output from the modules is essentially a sine wave, although 100 kHz and 10 kHz square wave output is available from the 1114-P2 and 1114-P3 respectively. The first divider 1114-P1 is a regenerative 5:1 divider, 1114-P2 thru 1114-P5 are switching type 10:1 dividers. The plug-in modules are designed to only fit in the correct slot. A switch behind the front cover selects the driving signal from 1 MHz 1114-P1 divider and an external 1 Mhz or 100 kHz inputs.

Specifications

  • Input: 5 MHz, 1 MHz, 100 kHz, 50 Ω. 1 V ±50%.
  • Output: with 5 MHz input
    • Sine Waves: 1 mHz, 100 kHz, 10 kHz, 100 Hz; 400 Hz and 60 Hz optional
    • Square Waves: 100 kHz, 10 kHz
  • Spurious Signals: better than 34 db down
  • Jitter: less than 500 μs for 100 Hz output with respect to 5 MHz input

Links

Photos

GR 1114-P1

GR 1114-P2

GR 1114-P3

GR 1114-P4

GR 1114-P5