1409-X: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{GR Product
{{GR Product
|model=1409-X
|model=1409-X
|codes=1409-1409-9721
|codes=1409-1409-9724
|class=Capacitance Standards
|class=Capacitance Standards
|summary=0.5μF,0.05% Standard Capacitor
|summary=0.5μF,0.05% Standard Capacitor
|image=Photo Needed.jpg
|image=GR 1409-X Front.jpg
|caption=General Radio 1409-X Standard Capacitor
|caption=General Radio 1409-X Standard Capacitor
|series=1409
|series=1409
Line 16: Line 16:
The {{Title|General Radio General Radio 1409-X Standard Capacitor}} was introduced in {{Catalog O}} and remained available through {{Catalog U}}.  
The {{Title|General Radio General Radio 1409-X Standard Capacitor}} was introduced in {{Catalog O}} and remained available through {{Catalog U}}.  


The 1409-X is a fixed mica capacitor of very high stability for use as two or three-terminal capacitance standards in the laboratory. The capacitor is installed in an aluminum case along with Silica gel desiccant then sealed with hi-temp potting wax. A well located on the right side of the case for the insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case and removable plugs on the bottom, for convenient parallel connection without error. Each capacitor is supplied with a certificate of calibration giving two and three terminal measured capacitance. The Type 1409-X capacitor is mounted in the small case.
The 1409-X is a fixed mica capacitor of very high stability for use as two or three-terminal capacitance standards in the laboratory. The capacitor is installed in an aluminum case along with Silica gel desiccant then sealed with hi-temp potting wax. A well located on the right side of the case for the insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case and removable plugs on the bottom, for convenient parallel connection without error. Each capacitor is supplied with a certificate of calibration giving two and three terminal measured capacitance. The Type 1409-X capacitor is mounted in the medium case.


See [[1409]] to view all the capacitors in the series.
See [[1409]] to view all the capacitors in the series.
Line 40: Line 40:
GR 1209 Figure 2.jpg|Dissipation factor as a function of frequency.
GR 1209 Figure 2.jpg|Dissipation factor as a function of frequency.
GR 1409 Technical Drawing.jpg|Technical Drawing.
GR 1409 Technical Drawing.jpg|Technical Drawing.
Photo Needed.jpg
GR 1409-X Front.jpg
GR 1409 Small Case Left.jpg| Thermometer Access
GR 1409-X Terminal Medium Case.jpg
GR 1409 Small Case Right.jpg
GR 1409-X Bottom Medium Case.jpg
GR 1409 Small Case Top.jpg
GR 1409 Small Case Bottom.jpg
GR 1409 Small Case Back.jpg
</gallery>
</gallery>


[[Category:Capacitance Standards]]
[[Category:Capacitance Standards]]

Latest revision as of 17:24, 12 July 2024

General Radio 1409-X
0.5μF,0.05% Standard Capacitor
General Radio 1409-X Standard Capacitor

Available from 1956 to 1970

Manuals
  • Manual Needed.
Catalog History
 Document Year Page
Catalog O 1956 156
Catalog P 1959 169
Catalog Q 1961 163
Catalog R 1963 152
Catalog S 1965 192
Catalog T 1968 89
Catalog U 1970 115
(All manuals in PDF format unless noted otherwise)

The General Radio General Radio 1409-X Standard Capacitor was introduced in Catalog O (1956) and remained available through Catalog U (1970).

The 1409-X is a fixed mica capacitor of very high stability for use as two or three-terminal capacitance standards in the laboratory. The capacitor is installed in an aluminum case along with Silica gel desiccant then sealed with hi-temp potting wax. A well located on the right side of the case for the insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case and removable plugs on the bottom, for convenient parallel connection without error. Each capacitor is supplied with a certificate of calibration giving two and three terminal measured capacitance. The Type 1409-X capacitor is mounted in the medium case.

See 1409 to view all the capacitors in the series.

Specifications

  • Capacitance: 0.5 μF
  • Series Inductance: 0.055 μH
  • Adjustment Accuracy: within ±0.05%
  • Stability: Capacitance change is less than 0.01% per year
  • Temperature Coefficient: capacitance; +35 ± 10 ppm per degree between 10 °C and 70 °C
  • Dissipation Factor: Less than 0.0003 at 1 kHz and 23 °C (see curves). Measured dissipation factor at 1 kHz is stated in the certificate to an accuracy of ±0.00005
  • Leakage Resistance: 5000 ohm-farads or 100 GΩ, whichever is the lesser
  • Maximum Voltage: 500 V peak below 35 kHz